ONWA Repair Tips




Search: ONWA
Results 127
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Bush ONWA
DeadFit a power supply kit from SEME RK215 for a safer and reliable repair
Goodmans 1430RA ONWA
Volume up full, red bargraph but no sound, Picture bargraphs also at full and will not adjustDisconnect pin 1 of MN1220, press vol down then store then resolder pin 1 - only seems to correct problem if resoldered while unit is powered.
Jvc C14ET1EK ONWA
Picture height is reduced to 2 inchesReplace C418. It's the coupling capacitor from the frame circuit to the scanning coils. It's value is 1000uF, 25V
Teac CT-M685 ONWA
Set stays in standby intermittantly or will int switch off to standby also brightness and contrast slightly lowResolder all joints in the power supply very small dry joints that need a microscope to find ! also check / replace replace capacitors C109 and C110 and check condition of other psu caps.
Jvc C-V14EKS/B/W Onwa
No RedI was hoping the nvm had become corrupt and turned the red drive down but it was fine To enter service mode press and hold vol up and vol down on the front panel and switch set on. Thankfully ZD405 8V2 had expired almost s/c and removed the red
Ssang YongOnwa
Int line & field twitchR423 100k hi res
PerdioCT1411 Onwa
Field collapseR414 12R o/c, ZD401 12v zener s/c - also check C909 47µ 50v, C910 10µ 50v & ZD901 8v2 zener
Matsui2039 Onwa
Dim pic with field cramp & poss loss of colR419 5R6 3w hi res
Matsui2038 Onwa
Still Dead aft replacement of C909/911 47µR417 2k2 5w (line dr supply) o/c
Matsui2038 Onwa
No sigs & no tuning voltsQ608
Matsui2038 Onwa
DeadC909/911 457µ 50v, ZD401 12v zener s/c, R419 5R6 3w hi res
Matsui1455 Onwa
Sweep tuning slow - no remote or sound.Replace X401 4MHz Xtal 63044004AA.
Matsui1455 Onwa
Stuck in standby.C613 leaky.
Matsui1455 Onwa
STUCK IN STANDBYC613 ( 0.0047 1KV )
Matsui1455 Onwa
SET STAYS ON IN STBY WHEN SWITCHED OUT OF STBY PICQ605 SC
Matsui1455 Onwa
PIC HEIGHT REDUCED AT BOTTOMR305 ( 24K ) GONE HIGH
Matsui1455 Onwa
PIC AND SOUND INT. . TAP LOPTY IF CLEARS FAULTCHECK SCREW NEAR C316
Matsui1455 Onwa
PATTERNING ON SCREEN IF CONTRAST TURNED LOW HUM BAC604 100uF 400v
Matsui1455 Onwa
Overbright raster.Q201 s/c.
Matsui1455 Onwa
No sync.R274